Headed Anchor Studs are used in all types of concrete connectins. they can be welded to a flat surface, or in the fillet, or on the heel of an angle with a stud welding system.
Ferrules:All orders for studs include required ferrules.
Length: Length is before weld. Stud diameters (D) 1/2 inch and below will be approximately 1/8 inch shorter after welding. 5/8 inch will be approximateley 3/16 inch shorter after welding. Made to order lengths are available upon request.
Material |
Low Carbon Steel (1010-1020) ASTM A29 |
Stud Diameter |
1/4 |
Stud Standard Length |
4-1/8 |
Stud Head Diameter |
.50 |
Stud Head Thickness |
.187 |
Ferrule Part # |
FER04-F (9000-04-F) |
Min. Tensile Strength Type A (psi) |
61,000 |
Min. Tensile Strength TYPE A (mpa) |
420 |
Min. Yield Strength (.02% offset) Type A (psi) |
49,000 |
Min. Yield Strength (.02% offset) Type A (mpa) |
340 |
Min. Elongation (% in 2 inch)-Type A (%) |
17 |
Min. Elongation (% in 5 x diameter) Type A (%) |
14 |
Min. Reduction of Area-Type A (%) |
50 |
RECOMMENDED STUD WELDERS FOR THESE STUDS (CLICK HERE)
|