Headed Anchor Studs are used in all types of concrete connectins. they can be welded to a flat surface, or in the fillet, or on the heel of an angle with a stud welding system.
Ferrules:All orders for studs include required ferrules.
Length: Length is before weld. Stud diameters (D) 1/2 inch and below will be approximately 1/8 inch shorter after welding. 5/8 inch will be approximateley 3/16 inch shorter after welding. Made to order lengths are available upon request.
Material |
Low Carbon Steel (1010-1020) ASTM A29 |
Stud Diameter |
5/8 |
Stud Standard Length |
9-3/16 |
Stud Head Diameter |
1.25 |
Stud Head Thickness |
.187 |
Ferrule Part # |
FER10-F (9000-10-F) |
| Mechanical Property Requirements |
| |
Type A |
Type B |
| Tensile Strength |
61,000 psi min. |
65,000 psi min |
| Yield Strength |
49,000 psi min |
51,000 psi min |
Elongation
(% in 2 in) |
17% min. |
20% min. |
Elongation
(% in 5x dia.) |
14% min. |
15% min. |
| Reduction of Area |
50% min. |
50% min. |
Type A Studs are general purpose studs
Type B Studs are headed, bent, or of other configuration that are used as an essential component in composite beam design |
RECOMMENDED STUD WELDERS FOR THESE STUDS (CLICK HERE)
|